S5 Retrofit
Why retrofit a Siemens S5 PLC??
In any manufacturing environment one of the key targets is to be as efficient and productive as possible. This can be achieved through any number of means, but one is to use data gathered from the factory floor, analyse it and from the results establish where there is room for improvement.
For example, it is often found that there is an information “black hole” between the production and management levels. If this gap is closed it becomes possible to provide real-time production data to the MES system, which in turn facilitates the fine-tuning of the manufacturing process.
One option is to standardise onto TCP/IP over Ethernet as the preferred communication channel between the IT world and production lines. However, this involves connecting all S5 PLC controlled production lines via Ethernet to the MES system.
One way to tackle this is to equip each S5 PLC with an Ethernet Communication Processor (CP). However, this approach does have disadvantages:
- Since 2003 Siemens has gradually phased out the S5 PLC family making it increasingly difficult and expensive to obtain S5 components.
- If an S5 rack is already fully configured an S5 expansion rack must be used to add an Ethernet CP.
- When adding a CP making changes to the existing PLC program is unavoidable. This includes, shutting down productions, loading the new PLC application, and testing; all-in-all, a very expensive approach.
However, Softing Industrial Networks have an alternative to this: Echolink. Echolink is a serial to Ethernet converter that allows serial devices without a network interface to communicate over Ethernet. Echolink supports multiple types of serial interfaces: RS232, RS422, RS485, TTY (20 mA), MPI, or PPI.
echolink one2Serial
This combined with the S5-TCP/IP-100 communication module brings universal communication to TCP/IP as well as to ISO (H1) networks with 10/100 Mbps.
The main advantages of this approach are:
- No need for an additional CP
- No need for any program changes in the PLC (the commands necessary to read/write the PLC data are configured within Echolink)
- Echolink supports all transport and application protocols necessary to allow programming and data access over Ethernet
The Retrofit Kit:
Here at Hitex we have the right products available to enable you to achieve this increased efficiency:
Echolink one2Serial

Interface module for easy Ethernet integration of SIMATIC S5 PLC via PG-Port.
- Easy configuration without programming
- Supports data exchange via TCP/IP( RFC1006)
- Easy and robust device mounting in cabinet
- Programming and Visualisation at the same time
- Supports Step 5
- A large number of diagnosis LEDs signal the state of the device